The investigators recently evaluated 4 different oximeters among the most commonly used with arterial catheter in place and compared SpO2 with SaO2 obtained on arterial gas. Correlations between SaO2 and SpO2 were poor for all oximeters, as previously known, and SpO2-SaO2 bias were different between oximeters. Some oximeters (Masimo, Nellcor) had lower biases but they detected less well hypoxemia.…
Trial Locations
Loading…

Loading trial locations…

Eligibility Criteria
Inclusion Criteria: * ≥ 18 years of age * Patients admitted to postoperative cardiac surgery intensive care unit * Presence of an arterial catheter Specific for the extubate patient * Ongoing on conventional oxygen therapy at moderate flow (up to a maximum of 5L/min) with SpO2 between 88 and 100% w…